Hydraulic Cylinder Configuration Tool

Enter the key cylinder dimensions, mounting, ports, connections, and operating conditions to create a hydraulic cylinder configuration sheet for engineering review and quotation.

Display Units
Step 1 of 4Structure & Geometry
Step 01

Structure & Geometry

Enter the main cylinder dimensions and mounting style.
mm
mm
mm
Head Flange (Rod End)
Cap Flange (Cap End)
Side Lug
Cap Fixed Clevis
Intermediate Fixed Trunnion
Cap Spherical Bearing
?
Other / Not Sure
Mounting Recommendation
Answer only if you want a mounting suggestion. This does not replace engineering verification.
Configuration Summary

Hydraulic Cylinder Configuration Sheet

Configuration data and engineering screening are separated so unverified items are never shown as approved.
Hydraulic Cylinder Configuration
For Engineering Review
ReferenceHC-260902-0018 CreatedSep 2, 2026 PurposeQuotation / Review Primary UnitsMetric

01 Structure & Geometry

Bore Diameter
Rod Diameter
Stroke
Mounting Style

02 Ports & Connections

Port Standard / Size
Port Position ReferenceViewed From Rod End
Head-End Port Position
Cap-End Port Position
Rod End Style
Thread Size

03 Operating Parameters

System Operating Pressure

04 Fluid & Temperature

Working Fluid
Fluid Temperature Range

Calculated Reference Values

Theoretical Extension Force
Theoretical Retraction Force
Calculated for a single-rod cylinder using the entered system operating pressure as working-side pressure. Opposing-chamber pressure, friction and pressure losses are not included.
Engineering ReviewPreliminary review only — final engineering verification required
Basic Geometry
Checked
Positive dimensions confirmed; rod diameter is less than bore diameter.
Port Standard / Size
Checked
Port standard and size designation are internally consistent.
Port Position
Checked
Standard Position 1 is selected.
Pressure Rating
Not Checked
Entered system pressure has not been checked against a verified cylinder pressure rating.
Port Machining Feasibility
Not Checked
Must be confirmed against bore size and final head/cap construction.
Mounting
Review Required
Selected mounting must be verified against load direction, alignment and machine structure.
Rod Buckling
Not Checked
Rod buckling was not evaluated; compression load, column length and end condition are required.
Buckling Screening Inputs
mm
Defaults to the entered rod diameter. Reduce this value if a smaller threaded or turned-down section governs the compression column.
kN
Use the actual compressive load when known. The theoretical extension force is not automatically treated as the application load.
mm
GPa
210 GPa (about 30.46 Mpsi) is a common steel reference value. Confirm actual rod material before final engineering approval.
Speed / Flow
Not Checked
Required cylinder speed and flow were not provided.
Seal / Fluid Compatibility
Not Checked
Working fluid and complete temperature range were not provided.