1/7

Replacement Hydraulic Cylinders for Parker Series HMI

Parker Series HMI is a tie-rod hydraulic cylinder series with a nominal pressure rating of Max. 210 bar. Bore sizes range from Ø25–200 mm, with rod diameters from Ø12–140 mm, depending on configuration.

Fangu manufactures replacement hydraulic cylinders for selected Parker Series HMI models. Replacement suitability is reviewed against the original model reference, bore, rod diameter, stroke, mounting, port connections, and operating requirements.

Key Specifications
Cylinder ConstructionTie-rod cylinder
Function ModeSingle Acting, Double Acting
Rod ConfigurationSingle Rod, Double Rod
Bore DiameterØ25–200 mm
Rod DiameterØ12–140 mm
Stroke LengthAny practical stroke
Nominal PressureMax. 210 bar
Port Size Options#6, #10, #12, #16, #20, 1/4 in, 3/8 in, 1/2 in, 3/4 in, 1 in, 1 1/4 in, M14×1.5, M18×1.5, M22×1.5, M27×2, M33×2, M42×2
Port Type OptionsSAE ORB, NPTF, BSPP, BSPT, Metric Thread, ISO 6149-1, SAE Code 61 Flange
01

Model References

Model / Part Number Bore Diameter Rod Diameter(s) Stroke Mounting Style
80 mm 36 mm 300 mm Cap Fixed Eye
80 mm 36 mm 300 mm Cap Fixed Clevis
80 mm 36 mm 300 mm Side Lug
80 mm 36 mm 300 mm Head Trunnion
80 mm 36 mm 300 mm Cap Trunnion
80 mm 36 mm 300 mm Intermediate Fixed Trunnion
80 mm 36 mm 300 mm Cap Rectangular Flange
80 mm 36 mm 300 mm Head Rectangular Flange
80 mm 36 mm 300 mm Cap Fixed Eye with Spherical Bearing
80 mm 36 mm 300 mm Tie Rods Extended Head End
80 mm 36 mm 300 mm Tie Rods Extended Cap End
80 mm 36 mm 300 mm Tie Rods Extended Both Ends
Select a model to instantly load and synchronize database parameters below.
02

Dimensions & Mounting

Series: Parker Series HMI
Mounting OptionsTB, TC, TD, JJ, HH, C, B, BB, SB, D, DB, DD
Rod End OptionsUp to 3 Male and 3 Female per Bore
Dimensional StandardISO 6020-2
Port Size Options#6, #10, #12, #16, #20, 1/4 in, 3/8 in, 1/2 in, 3/4 in, 1 in, 1 1/4 in, M14×1.5, M18×1.5, M22×1.5, M27×2, M33×2, M42×2
Port Type OptionsSAE ORB, NPTF, BSPP, BSPT, Metric Thread, ISO 6149-1, SAE Code 61 Flange
Port Position OptionsTop, Right, Bottom, Left
03

Technical Specifications

Series: Parker Series HMI
Temperature Range-20 to +80 °C (standard seals) Cushioning OptionsOptional at Either End or Both Ends
Hydraulic FluidMineral Oil (HH, HL, HLP, HLP-D, HM, HV)
Seal Type OptionsStandard, LoadMaster, Low-Friction (Groups 1, 2, 5, 6, 7)
04

How to Measure Your Old Cylinder

Can't find your exact OEM model? Measure your existing cylinder to help identify a suitable replacement.

Bore Diameter

Measure tube inner diameter using caliper inside jaws.

Rod Diameter

Measure rod outer diameter vertically with outer jaws.

Stroke Length

Measure the rod travel from fully retracted to fully extended.

Pin-to-Pin Distance

Measure center-to-center distance between mounting pins.

05

Request a Quote

Tell us your requirements. Our engineering team will review your inquiry and respond promptly.

Request a Quote

Requirement Type *

Our technical team will review your information and provide technical feedback promptly.

06

FAQ

How should I confirm a Parker Series HMI replacement cylinder?

Match the OEM model code first, then verify bore, rod diameter, stroke, mounting style, port thread, port position and nominal pressure against the installed machine. A series name alone does not confirm dimensional or functional interchangeability.

Hydraulic cylinder selection guide.
Which dimensions must be checked for Parker Series HMI?

Confirm bore, rod diameter, stroke, mounting dimensions, retracted length and extended length from the original cylinder or drawing. One series can contain several mounting, rod-end and port arrangements, so approve the replacement from measured dimensions rather than the series label alone.

Bore, rod diameter and stroke guide.
How should the Parker Series HMI nominal pressure be verified?

Treat Max. 210 bar as the series rating, not automatic approval for every application. Check peak pressure, duty cycle, temperature, hydraulic fluid, load direction and the required safety margin before confirming the cylinder.

Hydraulic cylinder force calculation guide.
Which mounting and port details must match on a Parker Series HMI replacement?

Match the mounting code, pin or flange geometry, rod-end thread, port size, port type and head/cap port positions to the installed cylinder. A mismatch can change pin centers, hose routing, available clearance or installation loads even when the bore and stroke are correct.

Mounting and port selection checks.